Highly sensitive SF6 decomposition Service for gis

Highly sensitive SF6 decomposition Service for gis

In order to judge the inside insulation fault of SF6 insulated equipment, the gas-sensing properties to a series of characteristic SF6 decomposition components, SOF2, SO2F2, SO2, H2S, CF4, HF, and SF6, have been studied. In this study, a comparative study of these gas-sensing materials has been made in theoretical and experimental fields to find the optimal gas-sensing material, and put ...

[email protected]
News Detail
  • Phosphorene: A Promising Candidate for Highly Sensitive and

    May 05, 2017 · Decomposition Gas Sensors. Abstract: Phosphorene is a promising candidate for gas sensing materials. This letter describes our study of the adsorption of SF 6 and SF 6 decomposition gases (SO 2 and H 2 S) on phosphorene. We used first principles calculations to explore phosphorenepotential applications as gas sensor to diagnose the state of online gas insulated switchgear (GIS).

    Get Price
  • A highly sensitive and selective SnS2 monolayer sensor in

    Mar 01, 2021 · Therefore, the SnS 2 monolayer can effectively detect H 2 S if decomposition of SF 6 happens in high electrical response. Therefore, the SnS 2 monolayer is a good sensing material to detect H 2 S for the diagnosis of the insulation state of GIS. Download : Download high-res image (324KB) Download : Download full-size image; Fig. 6.

    Get Price
  • Highly sensitive SO 2 photoacoustic sensor for SF 6

    Highly sensitive SO 2 photoacoustic sensor for SF 6 decomposition detection using a compact mW-level diode-pumped solid-state laser emitting at 303 nm . X. UKUN. Y. IN, 1,2. L. EI. D. ONG, 1,2,*

    Get Price
  • (PDF) Highly Sensitive and Precise Analysis of SF6

    A ppb-level CO sensor based on multi-comb optical-feedback cavity enhanced absorption spectroscopy with a 2.3 μm diode laser was developed for SF6 decomposition analysis in electric power system....

    Get Price
  • OSA | Highly sensitive photoacoustic multicomponent gas

    A ppb-level photoacoustic multicomponent gas sensor system for sulfur hexafluoride (SF6) decomposition detection was developed by the use of two near-infrared (NIR) diode lasers and an ultraviolet (UV) solid-state laser. A telecommunication fiber amplifier module was used to boost up the excitation optical power from the two NIR lasers.

    Get Price
  • High sensitivity gas sensor to detect SF6 decomposition

    Oct 01, 2020 · Phosphorene: a promising candidate for highly sensitive and selective SF6 decomposition gas sensors

    Get Price
  • Janus MoSSe monolayer: A highly strain-sensitive gas sensing

    Aug 15, 2020 · In sum, we concluded that the Janus MoSSe monolayer is a highly strain-sensitive gas sensing material to detect SF 6 decompositions. Our work provide insight on the future experimental and theoretical studies on the Janus MoSSe monolayer as promising sensing materials to detect hazardous SF 6 decompositions.

    Get Price
  • Highly sensitive and selective polyaniline thin-film sensors

    Feb 01, 2015 · However, few studies that used PANI thin-film sensors to detect SF 6 decomposition gases have been performed. Therefore, in this study, PANI films were fabricated by drop-coating technique on a printed circuit board substrate. Gas-sensing performance of SF 6 decomposition gases (H 2 S, SO 2, SOF 2, and SO 2 F 2) were evaluated at room temperature. Other gas-sensing properties such as response and recovery times, selectivity, and stability were also explored.

    Get Price
  • (PDF) SF6 Decomposition Gas Sensor Based on GeP Monolayer: A

    And the results demonstrate that applying negative electric field can significantly enhance the sensitivity of GeP monolayer to SO2. Therefore, GeP monolayer is a potential candidate for highly...

    Get Price
  • Gas-Insulated Substations - GIS

    SF6 decomposes in the high temperature of an electric arc, but the decomposed gas recombines back into SF6 so well that it is not necessary to replenish the SF6 in GIS. There are some reactive decomposition byproducts formed because of the trace presence of moisture, air, and other contaminants. The quantities formed are very small.

    Get Price
  • Enhancement of Gas Sensing Characteristics of Multiwalled

    H 2 S and SO 2 are important gas components of decomposed SF 6 of partial discharge generated by insulation defects in gas-insulated switchgear (GIS). Therefore, H<sub2</subS and SO<sub2</sub detection is important in the state evaluation and fault diagnosis of GIS.

    Get Price
  • Highly sensitive photoacoustic multicomponent gas sensor for

    Highly sensitive photoacoustic multicomponent gas sensor for SF6 decomposition online monitoring XUKUN YIN, 1,2,3 LEI DONG,1,2,* HONGPENG WU,1,2 LEI ZHANG,1,2 WEIGUANG MA, 1,2 WANGBAO YIN,1,2 LIANTUAN XIAO,1,2 SUOTANG JIA,1,2 AND FRANK K. TITTEL 3 1State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser

    Get Price
  • Adsorption and gas-sensing properties of Pt2–GaNNTs for SF6

    Sep 15, 2020 · Under the high discharge energy of partial electric discharges, SF 6 gas decomposes into low-fluorine sulfides (SF x, x = 1–5),. Notably, these low-fluorine sulfides are unstable. They will quickly react with trace amounts of H 2 O and O 2 in a GIS into stable gases, such as H 2 S, SO 2, SO 2 F 2, and SOF 2,.

    Get Price
  • Detecting characteristics of SF6 decomposed gas sensor for

    Gas insulated switchgears (GISs) with SF6 gas with superior insulation and interruption performances used as an insulating medium have realized significant downsizing of substation facilities. GISs...

    Get Price
  • Infrared Spectrum Analysis of SF6 and SF6 Decomposition

    Download Citation | Infrared Spectrum Analysis of SF6 and SF6 Decomposition | Pressured SF6 gas is widely used in GIS for electrical insulation as well as for are extinction. And a chemical way

    Get Price
  • Implementation Of Treatment Recovery Of the SF6 Gas

    AVANTEC in their factory, removing the decomposition products. Generally, this paper describes the treatment and the recycling of a used gas. 2/ Introduction Fig.1. Typical 245 kV dead tank circuit breakers using SF6 gas as Fig. 2. Typical Gas Insulated Substation (GIS) 245 kV using SF6 gas as internal insulation and interrupting medium.

    Get Price
  • High Sensitivity and Selectivity of AsP Sensor in Detecting

    Aug 13, 2018 · With time going by, the internal insulation defects and aging in GIS equipment may cause partial discharge, which will decompose SF6into SO2, H2S, and other decomposition products4,5. These...

    Get Price
  • Sensors | Free Full-Text | Analysis of the Sensitivity of K

    Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not

    Get Price
  • End-of-life factors in high voltage gas insulated switchgear

    Jul 06, 2020 · For GIS with SF6 gas :Gas can be tested for decomposition products on-site using chemical reaction tubes that change colour in the presence of certain reactive gases. Tubes sensitive to SO2 and to HF are available. However, since HF reacts rapidly with metals to form metal fluorides, the use of tubes sensitive to HF is not recommended.

    Get Price
  • CN102445433A - SF6 decomposition gas infrared spectrum multi

    The invention discloses an SF6 decomposition gas infrared spectrum multi-component detection method and a device. According to the method, a chopped wave modulation wheel and a spectroscopical filtration wheel in a traditional non-dispersion infrared spectrum technology are combined into a whole, a modulation filtration wheel is utilized to realize simultaneous measurement of multi-component

    Get Price
  • Sensitivity Characteristic Analysis of Adsorbent-Mixed Carbon

    As important SF 6 decomposition characteristic component gases, the detection of variations in the concentrations of SO 2 and H 2 S is significant to determine the insulation level of SF 6 gas and the development conditions of PD. Moreover, such detection lays a solid foundation for further diagnosis and assessment of GIS equipment operating

    Get Price
  • Optical technology for detecting the decomposition products

    Technology for Detecting SF6 Decomposition Products. With the development of optical detection technology, researchers are pursuing higher detection accuracy, higher sensitivity, and faster detection time. Equally, it is hoped that the structure would be as simple and compact as possible for onsite or on-line monitoring.

    Get Price
  • On-line Detection of GIS and Tank-type Circuit Breaker PD Defects

    Be highly sensitive to GIS all kinds of discharge defects Cannot detect some defects, such as loose washer, moving dust. The attenuation is great and the detecting range is narrow, suitable for

    Get Price
  • Solvay Special Chemicals

    mean this technology is a highly competi-tive transmission medium in a broad range of applications. Our research and application department supports this application with their know-how about the initial production of SF 6/ N2 mixtures through to the separation of SF6/N2 mixtures at end of service life or whenever required.

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    In order to judge the inside insulation fault of SF6 insulated equipment, the gas-sensing properties to a series of characteristic SF6 decomposition components, SOF2, SO2F2, SO2, H2S, CF4, HF, and SF6, have been studied. In this study, a comparative study of these gas-sensing materials has been made in theoretical and experimental fields to find the optimal gas-sensing material, and put

    Get Price
  • DILO Arc By-products Measuring Device | Precise Measuring of

    With a response time of <15 seconds, self-sealing hoses and couplings, along with connections for discharge recovery systems, the SF 6 arc by-products analyzer is user friendly and emission free. During the operation of gas insulated switchgear decomposition products (SO2/SOF2) might occur after a breakdown, which has a negative impact on the gas quality in the circuit breaker as well as on the insulation properties.

    Get Price
  • Mechanism and Application of Carbon Nanotube Sensors in SF6

    Zhang et al. studied the gas sensitive response of Pd-SWCNT sensors to five kinds of SF 6 decomposition gases (SO 2 F 2, SOF 2, SO 2, H 2 S, and CF 4) through density functional theory and found that once exposed to adsorbed gases, the conductivity of nanotube would increase in the following order: SO 2 SOF 2 H 2 S, decrease when adsorbed

    Get Price
  • DILO Arc By-products Measuring Device - World Leader in SF6

    With a response time of <15 seconds, self-sealing hoses and couplings, along with connections for discharge recovery systems, the SF 6 arc by-products analyzer is user friendly and emission free. During the operation of gas insulated switchgear decomposition products (SO2/SOF2) might occur after a breakdown, which has a negative impact on the gas quality in the circuit breaker as well as on the insulation properties.

    Get Price
  • New SF6 Leakage Test Unit for GIS Components | TD World

    For highly challenging test objects, such as medium voltage GIS components, the leak test system can be configured with recovery and filling functions to be carried out inside the vacuum chamber. With this option, the admissible pressure difference between chamber and internal pressure of the test object is permanently monitored via system control.

    Get Price
edge-iconMaybe You Will Be Interested
toTop
Click avatar to contact us
Chat Online