News Center
NDIR smartgas Liquefaction System for cables

NDIR smartgas Liquefaction System for cables

The NDIR gas sensor comprises an optical waveguide, a light source at one end of the waveguide, at least one light detector at the end of the waveguide opposite the light source, a diffusion type...

[email protected]
News Detail
  • NDIR SENSORS FOR SF6 MEASUREMENT - smartGAS

    NDIR-SENSORS – HIGH TECHNOLOGY FOR YOUR APPLICATION SF6 (sulphur hexafluoride) is a non-com-bustible and non-toxic gas. Throughout the world it is used primarily for insulating electrical high-voltage switching systems, transformers and cables. It is also used as an etching gas in semiconductor produc-tion and as a tracer gas in environmental

    Get Price
  • smartGAS Mikrosensorik | smartGAS

    ANAREX from smartGAS is a family of highly accurate, ready-to-install multi-gas analysers. They are supplied as a ready-to-connect plug-and-play solution and impress with their stable measurement performance, easy and intuitive operation via touchscreen and simple sensor calibration.

    Get Price
  • NDIR Gas Sensor Modules - Electrical Optical Components, Inc.

    The Functional Principle of Smartgas Sensors & ModulesGas Sensors For The Process Measuring TechnologyGas Sensors For Ambient Air MonitoringThe IR principle uses the individual absorption spectrum of the gas being measured. The exact gas concentration is determined through precise quantitative analysis of this spectrum. Because of this, their gas sensors function very selectively and are virtually unaffected by other environmental factors or gases. The functional principle of our gas sensors: long-term stability and performance thanks to NDIR technology from smartGAS As all measured gases absorb in varying spectral ranges, a kind of “fingerprint” arises that allows very selective characterization without cross-sensitivities. Gas sensors from smartGAS possess an integrated electronic evaluation system that displays a simple to use concentration signal to you as the user and reliably compensates for all drift and temperature influences.

    Get Price
  • Our Products | Gas Sensors Detectors | smartGAS

    Our sensors are based on the non-dispersive infrared absorption of gases (NDIR technology). They fulfil the highest requirements in terms of accuracy, reliability and cost-effectiveness in process measurement and room air measurement. As a solution provider, we also develop customized sensor concepts for the applications of our customers. Our gas sensors don´t require wear parts or chemical reactants.

    Get Price
  • Applications of our gas sensors | smartGAS

    Gas sensors for the widest range of applications. Our high-performance gas sensors are based on the principle of non-dispersive infrared measuring technology (NDIR) and offer numerous advantages over conventional sensors. We exclusively use proven and reliable materials and high-quality optical components for our NDIR sensors in line with the motto Blue Performance.

    Get Price
  • HC Sensors | Sensors for methane gas | smartGAS

    HC sensors from smartGAS use NDIR technology to detect even minuscule concentrations of methane, propane and butane in the ambient air. They feature minimal drift, short response times and good selectivity. The sensors are available with measuring ranges of 5,000 ppm and 4.4 vol%, 5 vol%, 10 vol%, 50 vol% and 100 vol%.

    Get Price
  • Complete Gas Sensor Circuit Using Nondispersive Infrared (NDIR)

    NDIR gas sensing circuit (simplified schematic: all connections and decoupling not shown) circuit description. With the 200 mV common-mode voltage buffered by low noise amplifier ADA4528-1, the NTC and thermopile signal output meets the requirements of the ADuCM360 buffered mode input—AGND + 0.1 V to approximately AVDD − 0.1 V for ADuCM360 ADC buffered mode input.

    Get Price
  • SmartGAS | Gas Sensors | Sensors Transmitters

    SmartGAS gas sensors are exclusively based on the principle of the infra-red absorption of gases (NDIR technology) they fulfil the highest requirements regarding accuracy, reliability and cost-efficiency. smartGAS sensors are suitable for an extremely wide variety of applications both in process measuring technology and ambient air monitoring. smartGAS are a solutions provider for gas sensor technology and, as such, can offer individual concepts, customised to your respective requirements.

    Get Price
  • NDIR CO2 Sensor with UART-I2C and PTFE Filter - Seeed Studio

    This digital NDIR CO2 sensor comes with UART and I2C interfaces, built-in calibration functionality, and compact in size, making it widely applicable in greenhouses, poultry farms, transportation stations, and other application scenarios where CO2 level is needed.

    Get Price
  • Ndir gas sensor Manufacturers Suppliers, China ndir gas

    ndir gas sensor manufacturer/supplier, China ndir gas sensor manufacturer factory list, find qualified Chinese ndir gas sensor manufacturers, suppliers, factories, exporters wholesalers quickly on Made-in-China.com.

    Get Price
  • Accurate Multiple Gas Detection Module with NDIR - Electrical

    The SILAREX sensor platform from smartGAS detects multiple gases using NDIR (non-dispersive infrared absorption). SILAREX modules offer the selectivity, long-term stability and measuring accuracy of NDIR. The SILAREX solution allows multiple gases to be measured in the same module. It also has pressure compensation.

    Get Price
  • US5444249A - NDIR gas sensor - Google Patents

    The NDIR gas sensor comprises an optical waveguide, a light source at one end of the waveguide, at least one light detector at the end of the waveguide opposite the light source, a diffusion type...

    Get Price
  • NDIR Analyzers - Nova Analytical Systems

    This overview from Nova Analytical Systems outlines how they work, what gases they measure, and why they are essential for many industrial applications. Gases Analyzed by NDIR Analyzers. NDIR analyzers accommodate the analysis of a wide range of gases, including carbon dioxide (CO 2), carbon monoxide (CO), methane (CH 4), and sulfur dioxide (SO 2). Below we outline how NDIR analyzers are used to analyze these gases in different industrial applications.

    Get Price
  • Catalytic (CC) LEL and Infrared (NDIR) Combustible Gas Sensor

    TR1002_1_28_13 TR 1002: Catalytic (CC) LEL and Infrared (NDIR) Combustible Gas Sensor Performance January 28, 2013

    Get Price
  • GASSENSE NDIR SENSOR MANUAL - Euro Gas

    The GasSense NDIR gas sensor, with integrated transmitter, is an innovative measurement module for the detection of CO2, CO, N2O, CH4 or related hydrocarbons. The sensor can be easily integrated as an OEM component into controls, measurement systems and monitoring instruments.

    Get Price
  • Global Non-dispersive Infrared (NDIR) Gas Sensors Market

    Non-dispersive Infrared (NDIR) Gas Sensors is an advanced integrated information system for the management of all the aspects involved in operations such as financial, medical, administrative, legal, and compliance. These are some of the factors, which contribute to the Non-dispersive Infrared (NDIR) Gas Sensors market.

    Get Price
  • Smart Sensor Infrared | RC Systems

    Cables; Gases We Detect. Combustible; Toxic and Oxygen; Carbon Dioxide Infrared; Photoionization; Other; Applications. ZoneProtector Multi-point Monitoring (Meets NFPA 820) Ammonia Gas Detection; Gas Detection in Refrigeration System; Gas Detection in the Food and Beverage Business; Gas Detection in Wastewater Treatment and Collection Facilities

    Get Price
  • NDIR Gas Sensors - Electrical Optical Components, Inc.

    An NDIR gas sensor (nondispersive infrared sensors) is a simple spectroscopic device often used as gas detector. It is called nondispersive because the wavelength which passes through the sampling chamber is not pre-filtered. Instead a narrow bandpass (or NBP) filter is used before the detector.

    Get Price
  • NDIR Gas Analyzer NG 3000 - Bont Tech

    NG 3100 system cabinet. The pump draws the flue gas via the sampling device and the heated flue gas line into the system cabinet ad forces it through the analyzer. In order to minimize the adsorption and desorption effects of HCI and NH 3 ,the analysis system is designed to handle a high flow rate of approximately 600 l/h (21 ft3/hrs). The

    Get Price
  • New Interface Electronics for NDIR Gas Sensors Envirotech Online

    With the new interface electronics smartCONNECT 2 (sC 2) smartGAS (Germany) offers an option for easy integration of smartMODUL NDIR gas sensors into nearly every application. The analogue (0)4…20 mA output fulfils NAMUR standards and is therefore suited to detect cable breakages or short circuits.

    Get Price
  • NI DAQ Device Custom Cables, Replacement Connectors, and

    Mar 31, 2021 · If you are trying to create a custom DAQ cable, create a custom fixture or breakout, modify an existing cable, repair or replace the connector on your cable or printed circuit board (PCB), or require replacement jackscrews or jacksocket fasteners, this document provides descriptions, part numbers, and vendor information to achieve these tasks. Note that this article replaces KnowledgeBase

    Get Price
  • NDIR Sensor | Products Suppliers | Engineering360

    The SILAREX sensor platform from smartGAS detects multiple gases using NDIR (non-dispersive infrared absorption). SILAREX modules offer the selectivity, long-term stability and measuring accuracy of NDIR.

    Get Price
  • Refrigerant Transmitter - draeger.com

    Gas detection systems from Dräger make it possible to detect even the smallest leaks at an early stage and initiate corrective measures. This increases the safety of your system, reduces operating costs for refrigerants and electrical energy as well as making a significant contribution to climate protection.

    Get Price
  • NDIR gas sensors - PCN Europe

    With the silarex sensor, which is based on infrared absorption (NDIR), smartGAS Mikrosensorik GmbH opens new possibilities in this field. Besides the well-known advantages of the NDIR technique the new sensors can be integrated very easily into a measurement device with its I2C interface, which can be also used for calculation purposes.

    Get Price
  • New NDIR Gas Sensor for CO measurement in the vol. % range

    Dec 19, 2016 · smartGAS Mikrosensorik GmbH (Germany) – smartGAS is expanding its EVO series of NDIR gas sensors for the measurement of carbon monoxide (CO). The FLOWEVO CO (100 vol. %) complements the new series, which already includes the FLOWEVO CO (2000 ppm). The great importance of industrial CO measurement is addressed by smartGAS with the expansion of its EVO series.

    Get Price
  • Cubic SJH-5 Methane Sensor - GasLab.com

    Micro-Pump Kit includes all the tools you need to urilize the tube-cap adapters as part of a sampling sensor system. Nafion tubing i s a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur.

    Get Price
  • Why NDIR? | Senseair

    Furthermore, the interference from other gases in the measurements is minimal to zero for NDIR sensors, depending on which gas is to be measured. In regard to semiconductor sensors, they perform best in higher concentrations (2,000 – 10,000 ppm) and are cross-sensitive to humidity and temperature fluctuations.

    Get Price
  • NDIR Sensors for Gas Analysis - Electrical Optical Components

    NDIR sensors from smartGAS offer many advantages for successful process control and are ideal for use in gas analysis. Our NDIR sensors have a large spectrum of measurable gases and are especially convincing where it is important to have the utmost precision and reliability.

    Get Price
  • What is NDIR? | Oshino Lamps Ltd.

    In NDIR gas sensing, the higher output of an infrared source is, the more accurate a gas concentration measurement becomes. So high-power incandescent lamps in the mid-infrared wavelength region are used for high-precision CO2 sensors.

    Get Price