Nov 15, 2017 · Machine Learning and the Rise of Next Generation Network Intrusion Detection Systems. Like a traditional NIDS, the function of a Next Generation IDS/IPS is to detect a wide variety of network-based attacks perpetrated by threat actors and contain these attacks, where feasible, using appropriate controls.

[email protected]
News Detail
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the Electric

    the decomposition products and concentrations formed under actual conditions can vary depending on the equipment used and the type of electrical discharge (CIGRE 1997). 1 CIGRE (the International Council on Large Electric Systems) is a permanent non-governmental and non­ profit-making international association based in France.

    Get Price
  • Tracking Down the Greenhouse Gas SF6 with Infrared Thermography

    SF6 Gas Detection Development of SF6 Leak Detection • Early systems for detecting SF6 gas emissions relied on a combination of infrared imaging and active CO2 laser illumination. • Called Backscatter Absorption Gas Imaging (BAGI) – A CO2 laser is scanned over the target area

    Get Price
  • A New Concentration Detection System for SF6/N2 Mixture Gas

    A New Concentration Detection System for SF6/N2 Mixture Gas in Extra/Ultra High Voltage Power Transmission Systems . Abstract . This paper develops a new detection system, for the first time, to detect the gas concentrations of the SF6/N2 mixture in extra/ultra-high voltage power transmission systems. The concentrations of SF6 and

    Get Price
  • Rapidox SF6 - SF6 Products - Fixed Detection System by

    All data can be output to a PLC or building management system. The OLCT100-XPIR SF 6 long-life infrared detector is an ATEX rated 4-20mA analogue SF 6 gas transmitter designed for industrial applications in hazardous locations; the measurement range is 0-2,000ppm (the threshold limit value – or TLV, time-weighted average – for SF 6 is 1,000 ppm). Each detector has programmable INSTANT, STEL and TWA alarm thresholds.

    Get Price
  • Gas Insulated Ring Main Unit RVAC - Eaton

    Sulfur Hexafluoride (SF6) Gas The insulating and arc quenching medium -SF6 SF6 gas, previously used mainly in circuit breaker of higher voltage level and with successful achievements, has now been found into medium voltage load switching system in recent years. This change happens to systems all over the world, since each insula-

    Get Price
  • Optical technology for detecting the decomposition products

    Thus far, optical detection methods have been applied for detection of SF 6 decomposition products, and a few promising results have been obtained. We review the various optical technologies for detection of SF 6 decomposition products, introduce their principles and applications, and summarize some recent research progress.

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Nov 01, 2007 · Based on the previous description, the identified products in the SF 6 decomposition system were S 2 OF 10, CF 4, COF 2, F 2, HF, H 2 S, NF 3, F 2 O, SiF 4, SO 2, S 2 F 10, SF 4, SO 2 F 2, SOF 2, SOF 4 and S 2 O 2 F 10. For example , the hydrolysis reaction of SF 6 with water may occur in the presence of an unvented indoor combustion source to produce HF and H 2 SO 4.

    Get Price
  • Mechanism of Formation of SF Decomposition Gas Products and

    previously reports of detection methods and electrode surface for the decomposition products are shown in Table 1. Table 1. Identification of SF 6 decomposition products by different electrodes and methods. Decomposition products Electrode Detection method Ref. SO 2, SOF 2 Cu–Au IR 19 SiF 4, SOF 2, S 2 F 2, CuF 2 Cu MS 20 SO 2, SF 2, SO 2 F 4

    Get Price
  • Research on the detection of SF 6 decomposition products

    Main decomposition products of SF 6 are SOF 4 and SO 2 F 2, which can be detected by CO, SO 2 and H 2 S sensors [46,47] and KDHF molecular sieve. Many researches were carried out regarding the...

    Get Price
  • (PDF) The SF6 Decomposition Mechanism: Background and

    The result shows that: SF6 begins to decompose obviously at 300°C and the main decomposition components contain CO2, SO2F2, SOF2, SOF4, SO2 and H2S; the improvement of fault temperature will

    Get Price
  • Experimental study on the relationship between partial

    SF6 decomposition serves as an effective means for online fault detection and diagnosis of SF6 insulated equipments. The relationship between SF6 decomposition products and partial discharge (PD) in SF6 insulated equipments remains a significant theoretical and practical issue to be addressed. Based on the simulations of protrusion discharge, floating discharge and surface discharge in SF6

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    Cahier Technique Schneider Electric nO. 188 / p.3 SF6 properties, and use in MV and HV switchgear Contents 1 Introduction 1.1 A brief history of use of SF6 p.4 1.2 SF6 manufacture p.5

    Get Price
  • High sensitivity gas sensor to detect SF6 decomposition

    Oct 01, 2020 · Mechanism and application of carbon nanotube sensors in SF6 decomposed production detection: a review Nanoscale Res. Lett. , 12 ( 1 ) ( Dec 2017 ) , p. 177 , 10.1186/s11671-017-1945-8

    Get Price
  • Adsorption of SF6 Decomposed Products on ZnO-Modified C3N: A

    Sep 25, 2020 · Abstract. SF 6, as an outstanding insulation medium, is widely used in the high-voltage insulation devices, guaranteeing the safe operation of the power system. Nevertheless, the inevitable partial discharge in a long-running device causes the decomposition of SF 6 and deteriorates its insulation performance. In this work, DFT calculations were performed to study the adsorbing and sensing properties of ZnO-modified C 3 N (ZnO-C 3 N) nanosheet towards SF 6 decomposed products, in order to

    Get Price
  • Chemical Detection of SF6 Decomposition Products Generated by

    This paper describes application of carbon nanotube (CNT) gas sensor to chemical detection of sulfur hexafluoride (SF6) decomposition products generated by AC or DC corona discharge, aiming to develop a new diagnosis method of gas-insulated switchgear (GIS) filled with high pressure SF6 gas.

    Get Price
  • Ni-CNT Chemical Sensor for SF6 Decomposition Components

    Oct 16, 2018 · In summary, the Ni-CNT gas sensor shows a high gas response to SF 6 decomposition components, and its high gas-sensing selectivity can be used to identify the gas types of SF 6 decomposition components produced in SF 6-insulated equipment, making it suitable to detect the insulation defects and diagnose the running status of SF 6 insulated equipment online.

    Get Price
  • Decomposition Characteristics of SF6 and Partial Discharge

    quantitatively detected by the gas chromatography/mass spectrometry (GC/MS) detection method. The decomposition characteristics of SF6 under four types of negative DC partial discharge (DC-PD) are obtained. The relationship between the decomposition characteristics of SF6 and the PD types was further studied.

    Get Price
  • SF6 Gas Discharge Decomposition Of Analyser Made in China

    SF6 Gas Discharge Decomposition Of Analyser. SF6 Gas Decomposition Tester uses the worldmost advanced UK Alpha high-performance, high resolution electrochemical sensors, embedded computer technology, is high-precision intelligent instrumentation.

    Get Price
  • SF6 Gas Decomposition Tester Made in China - SF6 Gas

    HZIR-3000 SF6 Gas Micro Leak Detection Test. HZIR-3000 SF6 Gas Micro Leak Detection Test Equipment 1. Purpose HZIR-3000 SF6 Quantitative leak detector is the most ideal test tools and methods of SF6 Micro leaks at present.It is efficient and accurate. 2. Technical specifications 3.Operating steps and instructions 1 、...

    Get Price
  • The SF6 Decomposition Mechanism: Background and Significance

    Jan 24, 2017 · Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decomposition phenomenon would greatly reduce the

    Get Price
  • Comparative Study of Materials to SF6 Decomposition

    Table 2. The typical decomposition components of SF 6 detected by TiO 2 nanotubes gas sensor. It is concluded that the Au-doped TiO 2 nanotubes sensor has better selectivity to SO 2 F 2 gas. Pt nanoparticles doping changes gas selectivity of TiO 2 nanotubes sensor to SO 2, SOF 2, and SO 2 F 2.

    Get Price
  • SF6 Gas Analysis - Cambridge Sensotec

    Rapidox SF6 Fixed Detection System A wide area monitoring solution to ensure safety for personnel working in, or who have access to, rooms that contain high voltage switchgear, circuit breakers and transformers where SF6 is at high pressure, the SF6 Fixed Detection System is used to monitor for SF6 leaks into this environment.

    Get Price
  • New IR SF6 Gas Detection Capability - International Gas Detectors

    We are proud to announce a new addition to our ever-expanding gas sensing range; with the release of our SF6 gas detection solutions. Our SF 6 gas detection equipment utilises world-leading, interference-free, non-dispersive infrared technology, both in a diffusion-based, non-ATEX detector and in our industry-leading 750 samplers.

    Get Price
  • Safety information for products Detector Tube SF6-products of

    Detector Tube SF6-products of decomposition D050017801 Revision no.: 3,00 Revision date: 17.08.2011 Print date: 17.08.2011 Page 7 of 7 H400 Very toxic to aquatic life. H410 Very toxic to aquatic life with long lasting effects. The information is based on present levels of our knowledge. It does not, however, give assurances of product properties

    Get Price
  • Multi - Functional Comprehensive Analysis SF6 Decomposition

    SF6 Decomposition Analyzer: Minimum Detection Amount: 0.1ppm: Repeatability: SO2, H2S ≤ 2%: Measurement Range: 0~100ppm (customizable) Temperature Humidity Range:-40℃ ~ +50℃, 95%RH Dimension: 252 X 310 X 98mm: High Light: sf6 gas leak detector, sf6 leak detection equipment

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE Journals

    Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • What is a Next Generation Network Intrusion Detection System?

    Nov 15, 2017 · Machine Learning and the Rise of Next Generation Network Intrusion Detection Systems. Like a traditional NIDS, the function of a Next Generation IDS/IPS is to detect a wide variety of network-based attacks perpetrated by threat actors and contain these attacks, where feasible, using appropriate controls.

    Get Price
  • Collisional Decomposition of SF6 | NIST

    Sep 01, 2000 · Abstract Insulating gas mixtures containing SF 6 have been promoted to serve as replacements for pure SF 6 in order to reduce SF 6 atmospheric emission. It has been argued that some synergism may be achieved by choosing proper buffer gases in mixtures with SF 6 such that the buffer gases efficiently slow down electrons into an energy range where the electron attachment cross section for SF 6

    Get Price
  • What Is a Next-Generation Intrusion Detection System? | CSO

    Apr 13, 2021 · What Is a Next-Generation Intrusion Detection System? Learn how time-strapped analysts can be more effective by integrating detection, investigation, and response workflows into a single tool.

    Get Price