News Center
Highly sensitive cf4 detection system for high-voltage switchgear

Highly sensitive cf4 detection system for high-voltage switchgear

SonaVu™, (powered by SDT) is a multi-frequency acoustic imaging camera that blends visual and auditory senses to faults that threaten the safety and reliability of electrical assets. With an array of 112 highly-sensitive ultrasound sensors, SonaVu™ listens to a wide field of detection which it displays on a 5" color screen.

[email protected]
News Detail
  • Highly sensitive glucose biosensor based on CF4-plasma

    Aug 06, 2010 · The plasma system employed in this study is composed of three main parts: (1) a reaction chamber, (2) radio-frequency generator, and (3) vacuum system. The electrodes are 0.15 m in diameter, and the shower-type anode and the cathode are aligned at the center and separated by 7 cm. The total operational pressure was controlled at 100 mTorr. 2.4.

    Get Price
  • Enhancement of Gas Sensing Characteristics of Multiwalled

    They found that MWNTs-based gas sensors obtained higher responses to H 2 S than those based on pristine nanotubes, but these sensors were not sensitive to SO 2. CF 4 is a commonly used plasma etching gas. It is a kind of fluoride gas. In this study, the surface of the MWNTs is modified by CF 4 plasma generated by DBD.

    Get Price
  • Electrical Inspection – UE Systems

    These highly sensitive, directional sensors double the detection distance of a standard scanning module and provide pinpoint accuracy. For more accurate diagnosis, ultrasound spectral analysis software helps identify sound patterns related to electrical emissions through spectral (FFT) and Time Series screens.

    Get Price
  • NUREG/CR-3122, 'Potentially Damaging Failure Modes of High

    lation combustibility and aging characteristics and thus use in ultra-high-voltage equipment, as well as to contribute expertise to the various stan-dard and code writing organizations. Reference 1. Gilbert Commonwealth Companies, GAISSARj Vol. 4 - Standard Safety Analysis Report. Docket STN 50-595 (July 31, 1978).

    Get Price
  • A highly sensitive and selective SnS2 monolayer sensor in

    Mar 01, 2021 · SnS 2 monolayer shows a high sensitivity for H 2 S detection, reaching to 63.5%. Overall, SnS 2 monolayer deserves to be further explored as a promising FET-based sensing candidate with high sensitivity to detect typical partial discharge gas (H 2 S) in SF 6-based gas-insulated switchgear.

    Get Price
  • PD Detector - IPEC Ltd

    The PD Detector is highly sensitive to the ultrasonic emissions produced by tracking and enable the onset to be detected before insulation failure. Switchgear – Gas Insulated (GIS) IPEC’s UHF (Ultra High Frequency) sensor is used to detect PD in EHV cable terminations, GIS (Gas Insulated Switchgear), GIL (Gas Insulated transmission Lines) GIT (Gas Insulated Transformers).

    Get Price
  • Hitachi ABB Power Grids, High Power High Voltage

    Mechanical Tests: All typical tests according to international standards (IEC 62271-100, 62271-102, 62271-203, 62271-104) performed on switchgear and components from 1 kV up to 800 kV Other Tests: Measurement of mechanical stress with strain gauges, bursting tests of enclosures, determination of SF -gas leakage rates of switchgear and GIS

    Get Price
  • iPec – PD Detector – All Measure

    Handheld Switchgear PD Detector with Data Synchronisation. The PD Detector is a dual transducer PD detector, with data synchronisation, for Switchgear. The instrument detects TEV signals generated by internal partial discharge as well as acoustic discharge generated by surface tracking or corona.

    Get Price
  • Continuous Monitoring of SF6 Degradation in High Voltage

    In high voltage SF<sub6</sub insulated switchgear, the level of SF<sub6</sub concentration needs to be monitored regularly because of its degradation by switching arcs and on-going partial

    Get Price
  • SF6 Sensors | Gas Insulated Switchgear (GIS) | smartGAS

    The high sensitivity and very small lower detection limit enable the 50 ppm sensor to detect even minimal sulphur hexafluoride leaks with absolute reliability. Another typical application for the highly sensitive FLOW EVO SF 6 sensor (50 ppm) is detection of SF 6 in environmental simulations. Since sulphur hexafluoride is not present in the atmosphere and non-flammable and non-toxic, it is used in very small concentrations as a tracer gas for real-time analyses of the spreading of fire gases

    Get Price
  • High and Medium Voltage Switchgear

    Efacec Switchgear has teams experienced in the development of medium and high voltage equipment with the use of advanced 3D software modeling and simulation of equipment operating under extreme conditions. It has implemented a strict quality system with emphasis on continuous improvement of equipment and manufacturing processes.

    Get Price
  • SF6 Portable and Fixed Leak Detectors

    Highly sensitive, detection guaranteed every time. SF6 LeakCheck P1:p is designed for the location, leak testing and measurement of SF6 leaks in high voltage electrical switchgear. The revolutionary SF6 leak detector rapidly detects leaks down to 1 x 10-8 ml/sec, with a response and clear down of less than 1 second.

    Get Price
  • iPec – PD-SGS TEV PD Detector – All Measure

    TEV – PD Detection. Partial discharge activity inside metal clad high voltage plant induces small voltage impulses called Transient Earth Voltages on the surface of the metal panels. TEVs travel around the surface to the outside of the switchgear where they can be picked up externally using capacitively coupled transducers. AE – PD Detection

    Get Price
  • Partial discharge early-warning through ultraviolet

    A system detection limit of 17 ppb per meter has been reached, and a ten-fold improvement in sensitive and uncertainty has been achieved for measuring sulfur dioxide concentrations.

    Get Price
  • PD-SGS: On-line Partial Discharge Spot Tester - IPEC LTD

    The PD Detector is highly sensitive to the ultrasonic emissions produced by tracking and enable the onset to be detected before insulation failure. Switchgear – Gas Insulated (GIS) IPEC’s UHF (Ultra High Frequency) sensor is used to detect PD in EHV cable terminations, GIS (Gas Insulated Switchgear), GIL (Gas Insulated transmission Lines) GIT (Gas Insulated Transformers).

    Get Price
  • On-line Partial Discharge Detector – Madhav Engineers

    The PD Detector is highly sensitive to the ultrasonic emissions produced by tracking and enable the onset to be detected before insulation failure. Switchgear – Gas Insulated (GIS) IPEC’s UHF (Ultra High Frequency) sensor is used to detect PD in EHV cable terminations, GIS (Gas Insulated Switchgear), GIL (Gas Insulated transmission Lines) GIT (Gas Insulated Transformers).

    Get Price
  • SF6 Leak Detection Application Note - Advanced Energy

    tion. The PAS technique is highly accurate and reliable. Ultra-high Sensitivity: With its very low detection limit (6 ppb SF. 6. in ambient), our 3731 system is a direct leak detection solution capable of integral monitoring of large switchgear rooms. It verifies that your GIS equipment operates below the

    Get Price
  • IPEC Test Equipments - Nemel Kenya

    PD Detection Partial Discharge activity inside metal clad high voltage plant induces small voltage impulses TEV (Transient Earth Voltages) on the surface of the metal cladding. TEVs travel around the cladding surface to the outside of the switchgear panel where they can be picked up externally using CC-TEV transducers.

    Get Price
  • OSA | Highly sensitive and selective CO sensor using a 2.33

    A ppm-level CO sensor based on a 2f wavelength modulation spectroscopy (2f-WMS) technique was developed for the application of SF6 decomposition analysis in an electric power system. A detailed investigation of the optimum target line selection was carried out to avoid spectral interference from high purity SF6 in a wide wavelength range. A diode laser emitting at 2.33 #x03BC;m and a 14.5-m

    Get Price
  • 3D Printing Technique-Improved Phase-Sensitive OTDR for

    The acoustic emission detection based on φ-OTDR system with highly sensitive cylindrical elastomers shows great advantages in the large-scale PD and breakdown discharge detection of HV equipment.

    Get Price
  • IET Digital Library: Optical sensing in condition monitoring

    Health monitoring of gas insulated apparatus is critical to improve the reliability and to reduce the life cycle cost. Among the various methods for monitoring, optical sensing developed fast in recent years due to their highly sensitive and anti-electromagnetic interference behaviour.

    Get Price
  • Switchboard Circuit Breaker Service - SIM Switchgear

    • SF6 gas leak detection using highly sensitive leak detection equipment • Contact resistance measurement • Insulation resistance measurement • High voltage DC impulse testing • Vacuum chamber inspections • Correct mechanism operation

    Get Price
  • doblePRIME PD-Guard Partial Discharge Monitor - Doble

    Mar 17, 2021 · For highly sensitive PD measurements with superposed line currents or high reactive currents (50/60 Hz) which can reach up to 300 A; LDWS-T sensor For use at HV cable terminations. For decoupling of PD signals (TNC-socket) High impedance version; For ungrounded and grounded devices UHF Drain Valve Sensor DN50/DN80 For use with HV Transformers.

    Get Price
  • High Voltage Testers - High Voltage Tester Manufacturer from

    High Voltage HVT-100 . AC High Voltage Tester that can be manually controlled with direct action onto the Variac. Our ac dielectric test system can be presented as a single rack unit with or without cage, or separated units (control on one side, transformer on the other side) according to the main international standards.

    Get Price
  • Detection of Partial Discharge Using Ultrasound Application

    Detection of Partial Discharge Using Ultrasound Switchgear inspection with a Permanently installed PDS Sensor In addition to airborne ultrasound, loose insulators, windings or even vibrating mechanical screw connections transmit ultrasonic waves into the equipment structure, that are not audible to the human ear. However, the highly sensitive

    Get Price
  • An Improved Partial Discharge Detection System Based on UV

    When the PD is weak, it would be difficult for the UVPD to detect the signal, thus the detection system must be highly sensitive [21,22,23,24]. Through circuit improvement and parameter optimization, the portability and sensitivity of UVPD device can be improved, and it meets the needs of routine inspections.

    Get Price
  • Partial Discharge Sensors | Qualitrol Corp

    Iris Power Epoxy Mica Capacitors (EMCs) are designed to detect Partial Discharge (PD) activity in electrical equipment such as switchgear, isolated phase bus, and dry type transformers without imposing on the equipment operation or reliability in any way.

    Get Price
  • Partial Discharge Testing with an Acoustic Imaging Camera

    SonaVu™, (powered by SDT) is a multi-frequency acoustic imaging camera that blends visual and auditory senses to faults that threaten the safety and reliability of electrical assets. With an array of 112 highly-sensitive ultrasound sensors, SonaVu™ listens to a wide field of detection which it displays on a 5” color screen.

    Get Price
  • Optical sensing in condition monitoring of gas insulated

    Nov 29, 2019 · This system was supposed to be applied for the fault diagnosis for GIS. H 2 S is another important decomposition product of SF 6, but there are few reports on the detection of H 2 S gas based on DOAS before. Zhang et al. established a UV‐DOAS platform to detect H 2 S and CS 2, and the detection system is shown in Fig. 16.

    Get Price
edge-iconMaybe You Will Be Interested
toTop
Click avatar to contact us
Chat Online