Full Scale/200: 1 turndown. Maximum Measurable Flow Rate: 128% full scale. Typical Response Time: 10 ms (adjustable) Warm-Up Time: <1 second. Mass Reference Conditions (STP): 25°C (77°F) and 14.696 psia (standard-others available on request) Operating Temperature: -10 to 50°C.

[email protected]
News Detail
  • SULFUR HEXAFLUORIDE by portable GC 6602

    MEASUREMENT TECHNIQUE: GAS CHROMATOGRAPHY (PORTABLE) ANALYTE: sulfur hexafluoride COLUMN: 38 cm x 6-mm OD stainless steel, packed with 100-120 mesh activated alumina DETECTOR: electron capture CALIBRATION: bag standards or calibrated gas mixtures RANGE: 0.1 to 10,000 ppb ESTIMATED LOD:0.05 ppb PRECISION (S r): 0.022 ACCURACY RANGE STUDIED: 0.1 to 200 ppb

    Get Price
  • RA-912F Portable SF6 Gas Laser Comprehensive Analyzer

    RA-912F Portable SF6 Gas Laser Comprehensive Analyzer. Classic polymer film humidity measurement SF6, when ambient humidity changes, the moisture sensitive components of the dielectric constant is changed, a corresponding change in the output electrical signal. Using the principle of SF6 gas spectral absorption measurements, rapid, without the interference of other gas components to better meet the needs of the site.

    Get Price
  • Sulfur Hexafluoride by Portable GC (6602) - Wikisource, the

    SULFUR HEXAFLUORIDE by portable GC SF6 MW: 146.06 METHOD: 6602 CAS: 2551-62-4 RTECS: WS4900000 EVALUATION: FULL OSHA : 1000 ppm NIOSH: 1000 ppm ACGIH: 1000 ppm (1 ppm = 5.97 mg/m 3 @ NTP) PROPERTIES: 6602 Issue 1: 15 August 1994 colorless, odorless gas; MP -50.8 °C; sublimes -63.8 °C; d = 5.0 (air = 1) SYNONYMS: (none) SAMPLING MEASUREMENT

    Get Price
  • Portable sulfur hexafluoride gas detector

    Handheld sulfur hexafluoride gas detector. Model. GASTiger 2000. Detection gas. Sulfur hexafluoride(SF6) in air. Working principle. TCD. Detection range. 0~10ppm, 0~50ppm, 0~100ppm (optional) Resolution. 0.01ppm(0~100ppm), 0.1ppm(0~1000ppm) Sampling method. Active pump suction, built in air pump can open or close independently. Flow speed: 500mL/min. Accuracy ≤±3% F.S.

    Get Price
  • Portable Infrared Gas Analyzer for SF6 ASHRAE 110 Fume Hood

    The InfraRan Analyzer -- a portable, mid-infrared specific vapor analyzer – is designed for easy, on-site measurement of sulfur hexafluoride (SF 6 ). It is ideal for fume hood evaluations as per ASHRAE 110, as well as determining airflow in ventilation systems, rooms and buildings. . The InfraRan Specific Vapor Analyzer provides accurate, on-site, real-time measurements and is factory calibrated for measuring SF 6 in the 0 - 5 parts per million (ppm) concentration range with resolution to

    Get Price
  • Sulfur hexafluoride analyzer, SF6 analyzer - All industrial

    Sulfur hexafluoride analyzers. PC with Windows based eSAM FT software for on-board data acquisition and processing - TOC measurement by FID possible, using the complementary Graphite 52M analyzer - Ideal for measuring trace concentrations SF6 analyzer 3-038R-R...

    Get Price
  • Ms104k Portable Sulfur Hexafluoride Sf6 Gas Leak Detector

    Ms104k Portable Sulfur Hexafluoride Sf6 Gas Leak Detector , Find Complete Details about Ms104k Portable Sulfur Hexafluoride Sf6 Gas Leak Detector,Handheld Sf6 Gas Monitor,Replace Bw Gas Alert Outdoor Or Indoor Toxic And Harmful Gas Analyzer Portable,Zigbee Gas Detector from Gas Analyzers Supplier or Manufacturer-Beijing Zetron Technology Co., Ltd.

    Get Price
  • Sulfur hexafluoride - Wikipedia

    Sulfur hexafluoride (SF 6) or sulphur hexafluoride (British spelling), is an extremely potent and persistent greenhouse gas that is primarily utilized as an electrical insulator and arc suppressant. [7] [8] It is inorganic , colorless, odorless, non- flammable , and non-toxic.

    Get Price
  • SF6 Transmitter

    The SF6 transmitter is ideally suited for the gas measurement of sulfur hexafluoride in the field of high voltage engineering. The transmitter can be used both as a gas leak detector and to monitor the gas quality in gas-insulated switchgear (GIS) or transformers.

    Get Price
  • sf6 gas analyzer, sf6 gas analyzer Suppliers and

    Sf6 Gas Analyzer Gas Analyzer Supplier Portable Flue Sf6 Sfd-600 So3 Refrigerant Gas Analyzer Sensors Inc For Field Measurements $309.00-$369.00 / Set 1.0 Sets (Min. Order)

    Get Price
  • Portable Continuous Sulfur Hexafluoride Detector 86 - 106kPa

    digital gas detector. Portable continuous sulfur hexafluoride detector 86 - 106kpa working pressure is a method of continuous detection of methane gas concentration in the nature of safety equipment, the use of imported non dispersive infrared technology sensor, can accurately and quickly detect the concentration of methane, effectively guarantee the life safety of the staff, intelligent level two alarm function greatly meet the requirements of industrial field safety monitoring equipment.

    Get Price
  • Kahn Instruments: Hygrometers

    Semiconductor Manufacturing - Dewpoint measurement of inert gases to the low parts per billion (ppb) level allows wafer and component manufacturers to produce high-quality parts. Sulfur Hexafluoride Monitoring - Sulfur hexafluoride (SF6) gas is used as an insulator in circuit breakers and transformers. Kahn hygrometers monitor the dew point of the SF6 to insure its integrity as an insulator.

    Get Price
  • Catalog of Guidelines and Standards for the Handling and

    Standard Specification for Sulfur Hexafluoride 2000 9 American Society for Testing and Materials (ASTM) Standard Test Method for Air and Carbon Tetrafluoride in Sulfur Hexafluoride by Gas Chromatography 1998 9 American Society for Testing and Materials (ASTM) Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1997 9

    Get Price
  • SF6 LeakCheck P1:P Sulfur Hexafluoride Leak Detector | Gastech

    MEASUREMENT PRINCIPLE: Negative Ion Capture (NIC) SENSITIVITY: Standard SF6 GasCheck P1 and LeakCheck P1: Highsense option 1 x 10-8 ml/sec, 0.1ppm, 0.001gm/yr SF6: RESPONSE: T90 = 1 second rise and clear downOPERATION: Lead acid battery, internal and fully protected,rRecharge between 85-265 AC V, 50/60Hz: ALARM: Audio and visual with an

    Get Price
  • About Us - Globeinstrument

    Henan Zhiyi System Engineering Co., Ltd a wholly-owned subsidiary of Henan Relations Co., Ltd , established in 2004 , The main scope of business is for the global market. Henan Zhiyi System Engineering Co., Ltd located in Zhengzhou National High-tech Industrial Development Zone, is a high-tech enterprise integrating RD, production, sales and services, engaged …

    Get Price
  • Portable SF6 Gas Density Monitors | Gas Density Monitoring

    Solon Manufacturing Company’s portable SF6 gas density monitors are a reliable and economical way to monitor SF6 gas density and leakage over a wide temperature range. Temperature-compensated pressure switches automatically adjust their settings to follow temperature changes for all SF6 density levels including mixed gases.

    Get Price
  • Portable Sulfur Analyzer | Products Suppliers | Engineering360

    Description: Portable flue gas analyzer adopts the unique long life time electrochemical techniques to measure the CO ,CO2 ,O2 ,SO2 ,NO2 ,NO and other gases in flue gas and to figure out excess air coefficient. This product has high precision, small volume, it is convenient to carry, simple to

    Get Price
  • FMA-PC16 Series | PORTABLE MASS FLOWMETER AND CALIBRATION KIT

    Omega’s FMA-PC16 Series portable digital mass flowmeters accurately and rapidly measure the mass flow rate, volumetric flow rate, pressure and temperature of process gases. The FMA-PC16 couples the FMA-1600A Series meter with fittings and tubing to create a portable gas chromatography calibrator. Omega’s FMA-PC16 Series portable calibration units combine up to three FMA-1600A Series or FMA-LP1600A Series mass flowmeters with totalizers and high-accuracy calibration inside a rugged

    Get Price
  • Sulfur hexafluoride | F6S - PubChem

    Sulfur hexafluoride is a sulfur coordination entity consisting of six fluorine atoms attached to a central sulfur atom. It is the most potent greenhouse gas currently known, with a global warming potential of 23,900 times that of CO2 over a 100 year period (SF6 has an estimated lifetime in the atmosphere of between 800 and 3,000 years).

    Get Price
  • SF6 room Measurement manufacturer

    Sulfur hexafluoride (SF6) Frequently Asked Questions. Put SF6 in at the exhaust hoods and measure inside the building to see if SF6 is getting back into the building. Measure the levels in the hoods, and in the work area. If the hoods are 100% effective you should not find any SF6 in the air.

    Get Price
  • Thermal Conductivity Analyzers | Nova Gas

    Sulfur Hexafluoride (SF6) Featuring a long-lasting thermal conductivity cell that provides accurate and stable readings, sulfur hexafluoride analyzers are rugged, waterproof pieces of technology that alert the user to the amount of sulfur hexafluoride present in a sample.

    Get Price
  • Portable Mass Flowmeter and Calibration Kit

    Full Scale/200: 1 turndown. Maximum Measurable Flow Rate: 128% full scale. Typical Response Time: 10 ms (adjustable) Warm-Up Time: <1 second. Mass Reference Conditions (STP): 25°C (77°F) and 14.696 psia (standard-others available on request) Operating Temperature: -10 to 50°C.

    Get Price
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the Electric

    Byproducts of Sulfur Hexafluoride (SF 6) Use in the Electric Power Industry Prepared for U.S. Environmental Protection Agency Office of Air and Radiation Global Programs Division 1200 Pennsylvania Avenue, NW Washington, DC 20460 Prepared by ICF Consulting 9300 Lee Highway Fairfax, VA 22031 January 2002

    Get Price
  • Industrial SF6 Gas Pressure and Measurement Products - WIKA USA

    SF 6 Gas Handling Equipment, Pressure Gauges, and Sensors . Sulfur hexafluoride (SF 6) is the insulator of choice for a variety of applications. Its electrical and thermal properties make it ideal for use in gas-insulated switchgear, breakers, and gas-insulated lines found in the transmission and distribution (TD) industry.

    Get Price
  • Portable Mass Flow Meter and Calibration Kit

    and Sulfur Hexafluoride U Pressure, Temperature and Volumetric and Mass Flow Simultaneously Displayed U NIST 5-Point Certificate Included U No Straight Runs of Pipe Required U RS232 and USB Standard TM FMA-PC16 Series Portable Mass Flow Meter and Calibration Kit FMA-PC16040509 shown closed. FMA-PC16040509 shown smaller than actual size.

    Get Price
  • "Short communication: Use of a portable, automated, open

    Abstract. The objective of this study was to measure enteric CH4 emissions using a new portable automated open-circuit gas quantification system (GQS) and the sulfur hexafluoride tracer technique (SF6) in midlactation Holstein cows housed in a tiestall barn. Sixteen cows averaging 176 ± 34 d in milk, 40.7 ± 6.1 kg of milk yield, and 685 ± 49 kg of body weight were randomly assigned to 1 out of 2 treatments according to a crossover design.

    Get Price
  • Htjl-V High Precision Sulfur Hexafluoride Quantita - SF6 Expert

    The measurement results are more accurate and the stability is better. The instrument is portable, and the probe and the host are split. Htjl-H 0.01ppm-500ppm High Precision Sulfur Hexafluoride.Get Price! RF08 Mini Series – modular. Mini Series as portable version with individual components. Wholesale Sf6 Gas Detector, Wholesale Sf6 Gas Detector.

    Get Price
  • Sulfur dioxide analyzer - All industrial manufacturers - Videos

    sulfur dioxide carbon monoxide flue gas oxygen carbon dioxide nitrogen oxide nitrogen dioxide CO2/02 nitrogen monoxide stack gas hydrogen sulfide methane process gas residual gas ammonia air hydrocarbon gas multigas fluoride nitrogen sulfur hexafluoride toxic gas carbon biogas natural gas total nitrogen. liquid (40)